Large Language Models for the National Radiological Technologist Licensure Examination in Japan: Cross-Sectional Comparative Benchmarking and Evaluation of Model-Generated Items Study
Bibliographic record
Abstract
Background: Mock examinations are widely used in health professional education to assess learning and prepare candidates for national licensure. However, instructor-written multiple-choice items can vary in difficulty, coverage, and clarity. Recently, large language models (LLMs) have achieved high accuracy in medical examinations, highlighting their potential for assisting item-bank development; however, their educational quality remains insufficiently characterized. Objective: This study aimed to (1) identify the most accurate LLM for the Japanese National Examination for Radiological Technologists and (2) use the top model to generate blueprint-aligned multiple-choice questions and evaluate their educational quality. Methods: Four LLMs-OpenAI o3, o4-mini, o4-mini-high (OpenAI), and Gemini 2.5 Flash (Google)-were evaluated on all 200 items of the 77th Japanese National Examination for Radiological Technologists in 2025. Accuracy was analyzed for overall items and for 173 nonimage items. The best-performing model (o3) then generated 192 original items across 14 subjects by matching the official blueprint (image-based items were excluded). Subject-matter experts (≥5 y as coordinators and routine mock examination authors) independently rated each generated item on five criteria using a 5-point scale (1=unacceptable, 5=adoptable): item difficulty, factual accuracy, accuracy of content coverage, appropriateness of wording, and instructional usefulness. Cochran Q with Bonferroni-adjusted McNemar tests compared model accuracies, and one-sided Wilcoxon signed-rank tests assessed whether the median ratings exceeded 4. Results: OpenAI o3 achieved the highest accuracy overall (90.0%; 95% CI 85.1%-93.4%) and on nonimage items (92.5%; 95% CI 87.6%-95.6%), significantly outperforming o4-mini on the full set (P=.02). Across models, accuracy differences on the non-image subset were not significant (Cochran Q, P=.10). Using o3, the 192 generated items received high expert ratings for item difficulty (mean, 4.29; 95% CI 4.11-4.46), factual accuracy (4.18; 95% CI 3.98-4.38), and content coverage (4.73; 95% CI 4.60-4.86). Ratings were comparatively lower for appropriateness of wording (3.92; 95% CI 3.73-4.11) and instructional usefulness (3.60; 95% CI 3.41-3.80). For these two criteria, the tests did not support a median rating >4 (one-sided Wilcoxon, P=.45 and P≥.99, respectively). Representative low-rated examples (ratings 1-2) and the rationale for those scores-such as ambiguous phrasing or generic explanations without linkage to stem cues-are provided in the supplementary materials. Conclusions: OpenAI o3 can generate radiological licensure items that align with national standards in terms of difficulty, factual correctness, and blueprint coverage. However, wording clarity and the pedagogical specificity of explanations were weaker and did not meet an adoptable threshold without further editorial refinement. These findings support a practical workflow in which LLMs draft syllabus-aligned items at scale, while faculty perform targeted edits to ensure clarity and formative feedback. Future studies should evaluate image-inclusive generation, use Application Programming Interface (API)-pinned model snapshots to increase reproducibility, and develop guidance to improve explanation quality for learner remediation.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.025 | 0.063 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.003 | 0.002 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.002 |
| Open science | 0.001 | 0.002 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".