MétaCan
Menu
Back to cohort
Record W4415778201 · doi:10.1136/bmjophth-2025-002509

Comparative outcomes of aflibercept biosimilars and reference aflibercept in nAMD: a systematic review and meta-analysis

2025· review· en· W4415778201 on OpenAlexaff
Korolos Sawires, Harrish Nithianandan, Sohel Somani

Bibliographic record

VenueBMJ Open Ophthalmology · 2025
Typereview
Languageen
FieldImmunology and Microbiology
TopicBiosimilars and Bioanalytical Methods
Canadian institutionsUniversity of TorontoBrampton Civic HospitalDalhousie University
Fundersnot available
KeywordsAfliberceptBiosimilarMEDLINEClinical trialClinical Practice

Abstract

fetched live from OpenAlex

OBJECTIVE: To evaluate the literature-pooled functional, anatomical and safety outcomes of aflibercept biosimilars compared with reference aflibercept for neovascular age-related macular degeneration (nAMD). METHODS AND ANALYSIS: Systematic review and meta-analysis. Medline, Embase and CENTRAL were searched from inception to 2 June 2025. Phase 3 randomised controlled trials (RCTs) comparing aflibercept biosimilars with the reference product in patients with nAMD were included. Two independent reviewers conducted screening, data extraction, risk of bias (RoB 2) assessment and certainty of evidence assessment (Grading of Recommendations, Assessment, Development and Evaluation), with a third reviewer resolving discrepancies. Primary outcomes included mean difference (MD) change in best-corrected visual acuity (BCVA) and retinal thickness over time, risk ratio (RR) for proportion of participants gaining >15 Early Treatment Diabetic Retinopathy Study (ETDRS) letters and RR for adverse events. Meta-regression was used to evaluate the temporal stability of continuous outcomes. RESULTS: Six RCTs involving 2044 participants (1026 biosimilar, 1018 reference) were included. Five aflibercept biosimilars were evaluated, representing more than 50% of the eight biosimilars currently approved worldwide. Meta-regression revealed no significant difference in MD change in BCVA over time between biosimilar and reference aflibercept (slope: 0.0321 letters/week; p=0.1013). For MD change in retinal thickness, an initial anatomical advantage for reference aflibercept at week 0 (intercept: 9.58 µm; p=0.0449) was not sustained over time (slope: -0.1685 µm/week; p=0.2303). The pooled RR for gaining >15 ETDRS letters from baseline was 1.19 (95% CI 0.98 to 1.45; p=0.079). No statistically significant differences were observed across 15 safety outcomes. CONCLUSION: This systematic review and meta-analysis found no statistically significant differences in functional, anatomical or safety outcomes between aflibercept biosimilars and the reference product for nAMD, based on moderate to high certainty evidence. Functional and anatomical outcomes appeared stable across multiple timepoints. Further long-term pharmacovigilance studies and real-world data beyond 56 weeks are warranted. PROSPERO REGISTRATION NUMBER: CRD420251048633.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.024
metaresearch head score (Gemma)0.047
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.024
Threshold uncertainty score0.127

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0240.047
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0240.043
Bibliometrics0.0090.008
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.002
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.318
GPT teacher head0.515
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueBMJ Open OphthalmologySame topicBiosimilars and Bioanalytical MethodsFrench-language works237,207