MétaCan
Menu
Back to cohort
Record W4416146036 · doi:10.1161/circep.125.014424

Safety and Efficacy of the Novel OmniaSecure Defibrillation Lead Through Long-Term Follow-Up: Final Results From the LEADR Trial

2025· article· en· W4416146036 on OpenAlexaff
George H. Crossley, Prashanthan Sanders, Bert Hansky, Paolo De Filippo, Maully J. Shah, Surinder Kaur Khelae, Travis D. Richardson, François Philippon, John S. Zakaib, Tessa Geelen, Katherin Arias, Baerbel Maus, Pamela Mason

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsUniversité LavalInstitut universitaire de cardiologie et de pneumologie de Québec
Fundersnot available
KeywordsLead (geology)DefibrillationReliability (semiconductor)Clinical trialVentricular fibrillationAtrial fibrillation

Abstract

fetched live from OpenAlex

BACKGROUND: The LEADR (Lead Evaluation for Defibrillation and Reliability) trial evaluated the small-diameter (4.7F), lumenless, integrated bipolar OmniaSecure defibrillation lead. The trial exceeded primary safety and efficacy objective thresholds, demonstrating favorable efficacy at implant and a low rate of complications. Three-year term outcomes of the LEADR trial assessing the OmniaSecure lead are reported here. METHODS: The LEADR trial is a prospective, multicenter, single-arm clinical trial. Patients with an indication for de novo implantable cardioverter defibrillator/cardiac resynchronization therapy defibrillator were implanted with the OmniaSecure lead in standard right ventricle locations and followed at prespecified intervals. The lead was evaluated for safety, efficacy, and reliability through final follow-up. RESULTS: There were 643/657 patients (97.9%) successfully implanted with the OmniaSecure lead with a mean follow-up of 32.4±9.1 months (26% female, 61.9±12.9 years). Pacing capture threshold, pacing impedance, and R-wave amplitudes remained stable throughout. There was a 96.5% freedom from major study lead-related complications at 3 years. At 3 years, 22.3% of patients received appropriate therapies, that is, shock and antitachycardia pacing, with a 75.4% antitachycardia pacing efficacy. Inappropriate shock rate was 2.7% and 5.9% at 1 and 3 years, respectively. CONCLUSIONS: The final results of the LEADR trial demonstrated 3-year term safety, efficacy, and reliability of the OmniaSecure lead, emphasizing the potential utility of this lead in a wide variety of patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.906
Threshold uncertainty score0.401

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.292
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207