MétaCan
Menu
Back to cohort
Record W4416207506 · doi:10.1302/1358-992x.2025.13.092

VOLAR VERSUS DORSAL PLATING IN CORRECTIVE OSTEOTOMY OF DISTAL RADIUS MALUNION: A META-ANALYSIS EXAMINING COMPLICATIONS, REOPERATIONS, AND HARDWARE REMOVAL RATES

2025· article· en· W4416207506 on OpenAlexaff
Jonathan Persitz, Ahmad Essa, Shawn Khan, Erez Avisar, A. Chan, Ryan Paul

Bibliographic record

VenueOrthopaedic Proceedings · 2025
Typearticle
Languageen
FieldMedicine
TopicOrthopedic Surgery and Rehabilitation
Canadian institutionsUniversity Health Network
Fundersnot available
KeywordsDorsumContext (archaeology)OsteotomyReduction (mathematics)Plating (geology)Odds ratio

Abstract

fetched live from OpenAlex

The primary objective of this meta-analysis is to systematically evaluate and compare complication, reoperation, and hardware removal rates between volar and dorsal plating in the context of corrective osteotomy for dorsally-angulated distal radius malunions. An extensive search across the MEDLINE, Embase, and CINAHL (Cumulative Index to Nursing and Allied Health Literature) databases was conducted to identify studies reporting outcomes following corrective osteotomy for dorsally-angulated distal radius malunions. Coprimary outcomes included: the occurrence of major complications, minor complications, reoperation, and hardware removal rates. Meta-analysis comparing each outcome with further meta-regression model based on surgical approach to compare the odds for each outcome was built. A total of 403 patients were included; 253 patients underwent volar corrective osteotomy and 150 underwent dorsal corrective osteotomy. Mean follow-up was 30 months. Volar plating was associated with fewer reoperations (9% vs. 28%), less hardware removal (3% vs. 18%) and comparable major complications (5% vs. 6%) compared to dorsal plating. The adjusted model showed a significant reduction (approximately 85%) in the odds of reoperation and hardware removal in the volar group. There was no difference in major or minor complications between the groups. This study shows that volar plating for dorsally angulated distal radial osteotomy significantly reduces the odds of reoperation and hardware removal compared to dorsal plating, even after careful adjustment for potential confounders.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.018
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.987
Threshold uncertainty score0.062

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.018
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0130.047
Bibliometrics0.0040.004
Science and technology studies0.0010.001
Scholarly communication0.0030.001
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.315
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designMeta-analysis
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueOrthopaedic ProceedingsSame topicOrthopedic Surgery and RehabilitationFrench-language works237,207