MétaCan
Menu
← Back to cohort
Record W4417123649 · doi:10.1038/s41598-025-31959-2

Development and evaluation of a mechanical chest compression device for standardized rodent cardiopulmonary resuscitation

2025· article· en· W4417123649 on OpenAlexfundno aff
Sam Brixius, Jakob Wollborn, Johannes Dinkelaker, Sonja Bröer, Rita Sanchez-Brandelik, Katharina Denzer, Martin Czerny, Georg Trummer, Felix Patricius Hans, Hans-Jörg Busch, Jan‐Steffen Pooth

Bibliographic record

VenueScientific Reports · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrest and Resuscitation
Canadian institutionsnot available
FundersSociety for Academic Emergency MedicineHeart and Stroke Foundation of CanadaEuropean Resuscitation CouncilAmerican Heart Association
KeywordsCardiopulmonary resuscitationCompression (physics)Thorax (insect anatomy)ReproducibilityResuscitationAnimal model

Abstract

fetched live from OpenAlex

Abstract Small animal models are indispensable in cardiopulmonary resuscitation (CPR) research. High-quality CPR, characterized by consistent chest compression rate, depth, and positioning is crucial for survival. However, achieving standardization in manual high-frequency chest compressions in small animal models remains technically challenging. This study evaluated the reproducibility of manual chest compressions and introduced a novel mechanical chest compression device (MCD) designed to improve consistency in rodent experiments. In an in vitro setup, manual compressions were performed by ten participants at target rates ranging from 100 to 260 bpm, guided by a metronome. Compressions performed on a fluid-filled polymer reservoir were analyzed for the compression rate, variability, and time within a ± 10% target range. A color indicator was used to assess the variability of the compression point. A small animal MCD was designed and tested under the same conditions. In vivo, 5 Sprague-Dawley rats underwent 5 min of electrically induced normothermic cardiac arrest followed by 8 min of external chest compressions using the MCD. Obtained data was compared to the in vitro results. A total of 21,650 manual and 20,098 mechanical compressions were analyzed. At 200 bpm, chest compressions using the MCD were significantly more precise (201 ± 1.2 bpm) than manual compressions (218 ± 21 bpm, p < 0.001) with a significant reduced compression point variability (1.7 ± 0.1 cm 2 vs. 10.8 ± 3.1 cm 2 , p < 0.001). Manual compressions maintained target rate in 58.8% of time compared to 100% for the MCD. In vivo testing confirmed these findings with chest compressions remaining within the target range 100% of the time and showing minimal rate variability (1.8 ± 1.7 bpm). These results highlight the limitations of manual chest compressions and demonstrate the potential of the MCD to enhance standardization and reproducibility in rodent CPR research.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.343
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueScientific Reports→Same topicCardiac Arrest and Resuscitation→French-language works237,207→