MétaCan
Menu
Back to cohort
Record W50222199 · doi:10.1055/s-0030-1248222

Reliability of Lower Limb Frontal Plane Alignment Measurements Using Plain Radiographs and Digitized Images

2010· article· en· W50222199 on OpenAlexaffabout
Adrian V. Specogna, Trevor B. Birmingham, Jerome DaSilva, Jaques S. Milner, Jacqueline Kerr, Michael A. Hunt, Ian Jones, Thomas R. Jenkyn, Peter Fowler, J. Robert Giffin

Bibliographic record

VenueThe Journal of Knee Surgery · 2010
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsWestern University
FundersArthrex
KeywordsIntraclass correlationMedicineStandard deviationRadiographyCoronal planeStandard errorReliability (semiconductor)AnkleOrthodonticsInterclass correlationNuclear medicineSurgeryAnatomyMathematicsStatisticsPhysics

Abstract

fetched live from OpenAlex

This study evaluated the reliability of lower limb frontal plane alignment measures obtained from plain radiographs measured manually and digitized images measured using a custom computer software package (TheHTO Pro; Fowler Kennedy Sport Medicine Clinic, London, Ontario, Canada). Radiographic measurements used in the planning of high tibial osteotomy, including the mechanical axis angle and mechanical axis deviation, were measured on 42 hip-to-ankle radiographs on two separate occasions by two different raters (A.V.S., J.J.D.). Intraclass correlation coefficients (0.96-0.99) indicated excellent agreement between the manual and computer measurements, suggesting both methods can be used interchangeably. Although test-retest and inter-rater reliability tended to be slightly better when using TheHTO Pro, intraclass correlation coefficients were excellent for both methods (0.97-0.99). The standard errors of measurement were <1 degree for mechanical axis angle and <2 mm for mechanical axis deviation, regardless of method or rater. Based on the observed standard errors of measurement, conservative estimates for the error associated with an individual's mechanical axis angle at one point is approximately 1.5 degrees, and the minimal detectable change on reassessment is approximately 2 degrees. The error associated with an individual's mechanical axis deviation at one point is approximately 4 mm, and the minimal detectable change on reassessment is approximately 6 mm. These results suggest that manual and computer measurements of lower limb frontal plane alignment can be calculated with minimal measurement error. However, the small errors associated with both methods should be considered when making clinical decisions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.037
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.045

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.037
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.255
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations119
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueThe Journal of Knee SurgerySame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207