MétaCan
Menu
← Back to cohort

Abstract 18065: Combining Echo Doppler and CT Derived LVOT Measurements Improve Accuracy of Continuity Equation Based Aortic Valve Area Determination

2014· article· en· W611070489 on OpenAlexaff
Sami Alnasser, Asim N. Cheema, Vamshi Kotha, Djeven P. Deva, Jeremy Edwards, Christopher E. Buller, Mark D. Peterson, David A. Latter, Osama Benhomeid, Laura Finken, Robert J. Chisholm

Bibliographic record

VenueCirculation · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsSt. Michael's Hospital
Fundersnot available
KeywordsMedicineVentricular outflow tractEcho (communications protocol)Nuclear medicineAortic valveCardiologyInternal medicineRadiology

Abstract

fetched live from OpenAlex

Background: Left ventricular outflow tract (LVOT) measurement by Echo falsely assumes circular LVOT with implications for aortic valve area (AVA) determined using continuity equation. In this study, we investigated the utility of combining Echo Doppler and computed tomography (CT) based LVOT area for precise AVA assessment. Methods: AVA-echo was calculated using continuity equation and standard echocardiography techniques. CT-LVOT area was measured by 3 independent readers. Blinded measurements were obtained in candidates for percutaneous aortic valve replacement. AVA-CT was calculated using CT-LVOT area and echo Doppler measurements. The inter-observer variability for CT-LVOT area and correlation between AVA-echo and AVA-CT was analyzed using intra-class (ICC) and Spearman correlation coefficient. Results: Complete data for 66 patients was analyzed. The ICC for CT derived LVOT measurement by three observers was 0.96 demonstrating excellent reliability. The LVOT area by echo was significantly smaller than that obtained by CT (3.43±0.8 vs. 4.45±1.2 cm2, p<0.0001) and showing moderate correlation (r=0.66, p=0.006). Similarly, the AVA-echo was significantly lower compared to AVA-CT (0.76±0.46 vs. 0.97±0.53 cm2, p<0.0001). The correlation coefficient for AVA-echo and AVA-CT was 0.7 (p < 0.0001), 0.4 (p=0.06) and 0.9 (p<0.0001) for AVA-echo of 0.8 cm2 respectively. The regression analysis showed that AVA-CT could be predicted by applying a correction factor to the AVA-echo as AVA-CT = AVA-echo x 1.1+0.14. Conclusion: CT provides accurate and reliable LVOT assessment. Combining CT-LVOT and echo Doppler measurements result in a larger AVA compared to AVA-echo representing a true anatomic measurement. These findings have important implications for grading of aortic stenosis and management of patients with moderate to severe aortic stenosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.018
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.028

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.018
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.298
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueCirculation→Same topicCardiac Imaging and Diagnostics→French-language works237,207→