MétaCan
Menu
Back to cohort
Record W6906537889 · doi:10.17632/27456wjx5s.4

Data of "Multi-institutional study on image quality for a novel CBCT solution on O-ring linac"

2025· dataset· en· W6906537889 on OpenAlexaff

Bibliographic record

VenueMendeley Data · 2025
Typedataset
Languageen
Field
Topic
Canadian institutionsNova Scotia Health Authority
Fundersnot available
KeywordsHounsfield scaleImage qualityCone beam computed tomographyImage resolutionConsistency (knowledge bases)Contrast (vision)Optical transfer functionDistortion (music)Quality (philosophy)

Abstract

fetched live from OpenAlex

Data of "Multi-institutional study on image quality for a novel CBCT solution on O-ring linac". Abstract Introduction: This work presents a multi-institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions. Methods: Phantoms for measuring relative electron density (RED) and image quality were sent to six institutions for imaging on Ethos and Halcyon units equipped with HyperSight CBCT. The imaging protocols included tube potential from 100 to 140 kVp and exposure from 80 to 800 mAs. Imaging performance was evaluated with regard to RED versus Hounsfield Units (HU), uniformity, contrast-to-noise ratio (CNR), slice thickness, circular symmetry, Modulation Transfer Function (MTF), and spatial resolution. Results: Among all institutions, some variability was observed among institutions in the RED-to-HU relationship, especially for RED values greater than 1, although no outliers were found (|z-score|<2 in all cases). In this range, RED/HU slopes were 475 ± 25 10-6 RED/HU at 100kVp, 505 ± 20 10-6 RED/HU at 125kVp, and 550 ± 20 10-6 RED/HU at 140kVp. Radial uniformity ranged from 1 to 7 HU, depending on protocol. Circular symmetry for two points 50 mm apart showed consistency within one-pixel dimension. Integral non-uniformity was between 1 to 10, with no difference observed between vertical and horizontal dimensions. Contrast rods with 1 % gave CNR=0.5, 1 and 2 for 100(88), 125(176) and 140(528) in kVp(mAs), and contrast rods with 0.5 % had CNR=0.2, 0.4 and 0.8 for 100(88), 125(176) and 140(528) in kVp(mAs). Spatial resolution given by MTF at 10 % and 50 % yielded values of 0.55 ± 0.01 mm-1 and 0.35 ± 0.02 mm-1, respectively. Conclusions: This multi-institutional analysis of CBCT imaging performance showed consistency in radial uniformity, circular symmetry, integral non-uniformity, contrast and spatial resolution. Some variability was seen in the RED-to-HU relationship for RED>1 depending on exposure. More data from different institutions would be necessary to establish more robust statistical metrics which ensure quality parameters. Agulles-Pedrós L, MacDonald RL, Cherpak AJ, et al.Multi-institutional study on image quality for a novel CBCT solution on O-ring linac. J Appl Clin Med Phys. 2025;e70023. https://doi.org/10.1002/acm2.70023

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Dataset · Consensus signal: none
Teacher disagreement score0.009
Threshold uncertainty score0.047

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.014
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.398
GPT teacher head0.479
Teacher spread0.082 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreDataset

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueMendeley DataFrench-language works237,207