MétaCan
Menu
Back to cohort
Record W6979323320

Consensus Recommendations for Hyperpolarized [1-13C]pyruvate MRI Multi-center Human Studies

2025· article· en· W6979323320 on OpenAlexfundno aff

Bibliographic record

VenueArXiv.org · 2025
Typearticle
Languageen
FieldChemistry
TopicAdvanced NMR Techniques and Applications
Canadian institutionsnot available
FundersUniversity of Texas MD Anderson Cancer CenterNational Institutes of HealthDanmarks Tekniske UniversitetRigshospitaletNational Cancer InstituteChang Gung Medical FoundationUniversity of TorontoEidgenössische Technische Hochschule ZürichUniversity College LondonAlbert-Ludwigs-Universität FreiburgNational Institute for Health and Care ResearchMemorial Sloan-Kettering Cancer CenterSunnybrook Research InstituteWashington University in St. LouisAarhus UniversitetUniversity of OxfordCancer Prevention and Research Institute of TexasTechnische Universität MünchenUniversity of NottinghamMenzies Centre for Australian Studies, King's College London, University of LondonAstraZeneca
KeywordsQuality assuranceBest practiceQuality (philosophy)Human researchClinical PracticeField (mathematics)MEDLINE
DOInot available

Abstract

fetched live from OpenAlex

Magnetic resonance imaging of hyperpolarized (HP) [1-13C]pyruvate allows in-vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. Consensus on best practice for multi-center studies is required to develop clinical applications. This paper presents the results of a 2-round formal consensus building exercise carried out by experts with HP [1-13C]pyruvate human study experience. Twenty-nine participants from 13 sites brought together expertise in pharmacy methods, MR physics, translational imaging, and data-analysis; with the goal of providing recommendations and best practice statements on conduct of multi-center human studies of HP [1-13C]pyruvate MRI. Overall, the group reached consensus on approximately two-thirds of 246 statements in the questionnaire, covering 'HP 13C-Pyruvate Preparation', 'MRI System Setup, Calibration, and Phantoms', 'Acquisition and Reconstruction', and 'Data Analysis and Quantification'. Consensus was present across categories, examples include that: (i) different HP pyruvate preparation methods could be used in human studies, but that the same release criteria have to be followed; (ii) site qualification and quality assurance must be performed with phantoms and that the same field strength must be used, but that the rest of the system setup and calibration methods could be determined by individual sites; (iii) the same pulse sequence and reconstruction methods were preferable, but the exact choice should be governed by the anatomical target; (iv) normalized metabolite area-under-curve (AUC) values and metabolite AUC were the preferred metabolism metrics. The work confirmed areas of consensus for multi-center study conduct and identified where further research is required to ascertain best practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.525
metaresearch head score (Gemma)0.520
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesMetaresearch
DomainCandidate signal: Methods · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.475
Threshold uncertainty score0.586

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.5250.520
Meta-epidemiology (narrow)0.0020.003
Meta-epidemiology (broad)0.0040.009
Bibliometrics0.0080.006
Science and technology studies0.0060.007
Scholarly communication0.0100.008
Open science0.0180.018
Research integrity0.0200.020
Insufficient payload (model declined to judge)0.0050.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.120
GPT teacher head0.411
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; the direct Gemma label and the distilled Codex classifier agree on what is shown here.

Study designNot applicable
DomainMethods
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueArXiv.orgSame topicAdvanced NMR Techniques and ApplicationsFrench-language works237,207