MétaCan
Menu
Back to cohort
Record W6990420202

Development and testing of a lab-in-a-tube biosensor

2023· dissertation· en· W6990420202 on OpenAlexfundno aff

Bibliographic record

VenueMacSphere (McMaster University) · 2023
Typedissertation
Languageen
FieldEngineering
TopicBiosensors and Analytical Detection
Canadian institutionsnot available
FundersMcMaster University
KeywordsBiosensorElectrodeAnalyteMicrofluidicsFabricationFootprint
DOInot available

Abstract

fetched live from OpenAlex

Early detection is crucial in delivering timely treatment and improving patient outcomes. Point-of-care (POC) biosensors play an essential role in early detection, allowing for rapid and accurate diagnosis of diseases at the patient’s bedside without the need for expensive equipment or specialized personnel. By performing the analysis on-site, POC diagnostics can offer continuous monitoring and real-time data acquisition of a patient's health status. Thus, there is strong incentive in creating POC biosensors to provide healthcare professionals with greater access to diagnostic information, ultimately improving outcomes and reducing healthcare costs. Herein, the development of a POC lab-in-a-tube biosensor that utilizes simple and scalable fabrication techniques is presented. Electrodes are patterned on low-cost plastic substrates, which can be subsequently rolled and heat-shrunk into miniaturized tubing for flow-through analysis of liquid samples. Heat-shrinking of the device results in 3-dimensional, hierarchically wrinkled electrodes with morphological feature that span several orders of magnitude in size. These wrinkled electrodes demonstrate dramatically increased surface area in a given footprint compared to traditional planar electrodes. Incorporation of modified gold and silver wires allows for sensitive and stable electrochemical detection, enabling fast and quantitative results. These devices are capable of millilitre-per-minute flow rates to allow for rapid sample processing and for increased mass-transport to the electrode surface. The ability to capture analytes was characterized with nucleic acid sequences using pump-driven and blood-collection tube induced flow for rapid and accurate detection. Overall, this work demonstrates the successful development of an electrochemical platform integrated into a plastic tubing capable of rapid detection of flowing analytes. With its ease-of-use and compatibility with a wide range of flow rates, the device has the potential to be incorporated with existing medical tubing and procedures to achieve POC diagnostics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.981
Threshold uncertainty score0.805

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.191
Teacher spread0.175 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueMacSphere (McMaster University)Same topicBiosensors and Analytical DetectionFrench-language works237,207