MétaCan
Menu
Back to cohort
Record W6999722679

Design and Modeling of Piezoelectric Micromachined Ultrasonic Transducer (PMUT) using a Multi-User MEMS Process for Medical Imaging

2020· dissertation· en· W6999722679 on OpenAlexaboutno aff

Bibliographic record

VenueScholarship at UWindsor (University of Windsor) · 2020
Typedissertation
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsnot available
Fundersnot available
KeywordsPMUTPiezoelectricityMicroelectromechanical systemsUltrasonic sensorTransducerCapacitive micromachined ultrasonic transducersMultiphysicsElectrical impedancePressure sensorCapacitance
DOInot available

Abstract

fetched live from OpenAlex

According to the Canadian Cancer Society, 2020, “1 in 8 women will be affected by breast cancer and 1 in 33 will die from it.” There has been a decline in breast cancer causalities due to the early detection using advanced imaging technologies. This signifies the importance of early detection of breast cancer that increases the survival rate and treatment options for the patients. One of the platforms which are aiding the early detection is Microelectromechanical Systems (MEMS)-base imaging system. In this thesis, a Piezoelectric Micromachined Ultrasonic Transducer (PMUT) is proposed to work at lower frequency ranges for higher penetration aiding imaging applications while operating at a lower voltage. In this work, a comprehensive study based on the Multi-User MEMS Process (MUMPs) has been conducted to investigate the effect of critical design parameters on output performance. Three sets of PMUTs are fabricated based on the investigated parameters. The resonant frequency and acoustic output pressure of these fabricated devices are evaluated and compared based on their respective areas of the piezo layer using COMSOL Multiphysics. The resonant frequency of the fabricated PMUT ranges from 0.5 MHz to 2 MHz. Keysight Impedance Analyzer E4990A has been utilized for the electrical characterization of the fabricated PMUT devices to determine their respective resonant frequencies and validate the COMSOL simulation results. It is shown that the fabricated individual circular PMUT achieves a high acoustic output pressure of 39 kPa at 1.3 MHz and the rectangular PMUT provides 4.7 kPa of acoustic pressure at 1.4 MHz. The results indicate that the proposed PMUT design can deliver acoustic pressure at a lower frequency

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.282
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueScholarship at UWindsor (University of Windsor)Same topicUltrasound Imaging and ElastographyFrench-language works237,207