MétaCan
Menu
Back to cohort
Record W7005828663

The shear bond strength of orthodontic bracket base shapes to human enamel, an in vitro study

2021· dissertation· en· W7005828663 on OpenAlexaff

Bibliographic record

VenueMspace (University of Manitoba) · 2021
Typedissertation
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsUniversity of Manitoba
Fundersnot available
KeywordsBracketAdhesiveBond strengthBase (topology)Shear (geology)Shear strength (soil)
DOInot available

Abstract

fetched live from OpenAlex

Introduction: There is a growing demand for esthetic appliances during orthodontic treatment, with a specific interest in WildSmiles shaped brackets amongst children and adolescents. Bond failure of brackets over the course of orthodontic treatment can result in increased treatment time, increased overhead costs, and feelings of frustration for the patient and practitioner. Objective: The purpose of this study was to the evaluate the effect of orthodontic bracket base shape on shear bond strength (SBS) to human enamel, in vitro, at two time points, as well as the nature of debonding fractures using the Adhesive Remnant Index (ARI). Methods: Orthodontic brackets with different shaped bases (flower, heart, rectangular) were bonded to 120 extracted human third molars. SBS was measured using a Servohydraulic Test System at 24 hours and 2 months after initial bonding. ARI scores were evaluated under 10x magnification to assess the amount of resin left on the tooth. Results: The control bracket with a rectangular base shape had the highest mean SBS (26.78 ± 8.19 MPa), and significantly differed from flower (17.19 ± 4.45 MPa) and heart (18.86 ± 3.50 MPa) base shapes (p < 0.001). The mean SBS of flower and heart shaped brackets did not differ considerably from each other (p > 0.05). The mean SBS between debond times at 24 hours (21.50 ± 7.46 MPa) and 2 months (20.38 ± 6.69 MPa) were not statistically significant (p > 0.05). Analysis of ARI scores showed a significant difference between Flower-24 hours vs Heart- 2 months (p=0.039), Flower-24 hours vs Heart- 24 hours (p=0.004), and Control-2 months vs Heart-24 hours (p=0.015). The heart shaped bracket had a greater proportion of adhesive bond failures at the enamel-resin interface. Conclusion: Bracket base shape has an effect on SBS, with the rectangular base shape having a higher mean SBS compared to flower and heart base shapes. All bracket shapes had bond strengths above the clinically acceptable range of 6-8 MPa, and thus may provide adequate SBS in a clinical situation. Variations in ARI scores occurred based on bracket shape and were of a mixed adhesive-cohesive nature.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.263
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueMspace (University of Manitoba)Same topicDental materials and restorationsFrench-language works237,207