MétaCan
Menu
Back to cohort
Record W7015099654

Self-attenuation in the low-energy range: an experimental study on 210Pb

2023· article· en· W7015099654 on OpenAlexaff

Bibliographic record

VenueHAL (Le Centre pour la Communication Scientifique Directe) · 2023
Typearticle
Languageen
FieldHealth Professions
TopicRadioactivity and Radon Measurements
Canadian institutionsHerzberg Institute of Astrophysics
Fundersnot available
KeywordsCalibrationRadionuclideSample (material)AttenuationMatrix (chemical analysis)Absorption (acoustics)Standard uncertaintySample preparationAnalytical Chemistry (journal)
DOInot available

Abstract

fetched live from OpenAlex

Quantitative analysis of environmental samples generally involves volume source with low radioactivity and an unknown composition of the sample matrix. Unless an efficiency calibration with the same geometry and matrix is available, it is necessary to correct the raw counting rates for self-attenuation effects in order to obtain the correct sample activity. This can be achieved either experimentally or by means of calculation based on mass attenuation coefficients that can be directly measured or taken from tabulated absorption data. The self-attenuation effect is more pronounced when the energy of the emitted photons is low. This is the case with 210Pb, which is a low-energy gamma emitting radionuclide (46.54 keV) suffering strong absorption in the sample matrix and whose concentration in the environment must be regularly monitored according to public health regulations. Within the framework of the GSWG, twelve laboratories agreed to carry out measurements with matrices containing 210Pb and to compare their approaches to the determination of self-attenuation correction factors in order to draft practical recommendations for users. With this aim, the Laboratoire National Henri Becquerel (LNHB) prepared two different sets of three samples, each packed in cylindrical containers with known activities of 210Pb and 137Cs, according to the preparation procedure using standard solutions. The sample filled with resin was meant to be considered as a standard source by the participants and could be used for the efficiency calibration of the detectors. The goal of the exercise was to determine the activity of the two radionuclides included in the other two samples, with unknown matrices. This required the participants to establish the self-attenuation correction factors between the calibration and the measurement matrices. Inactive matrices can be used to experimentally determine the attenuation coefficients for calculating self-absorption. The different approaches and results obtained by the participants are presented and general recommendations are proposed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.610
Threshold uncertainty score0.782

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0110.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.353
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueHAL (Le Centre pour la Communication Scientifique Directe)Same topicRadioactivity and Radon MeasurementsFrench-language works237,207