Abstract

fetched live from OpenAlex

Power flow between two transmission systems across an uncontrolled interface can be problematic if there is unequal sharing between the tie lines. System configuration changes such as generation dispatch, or out of service elements can cause thermal overloads. In addition, some weaker areas of the system which may have insufficient transmission can have difficultly supporting the voltage at buses with high loading particularly after the loss of one element. This thesis presents a real transmission system which has two problems: a thermal limitation caused by unequal tie-sharing across an uncontrolled interface, and a post-fault voltage stability concern. Various potential solutions are analyzed and shown to address one or the other of these two problems; none of which were capable of solving both. A Unified Power Flow Controller (UPFC) is proposed which can effectively address both problems and can provide additional benefit in the form of a grid storage interface. The operational characteristics of a UPFC are analyzed and used to develop an electrical model and control system topology. The model with its control system is implemented in PSCAD. The UPFC is proven to be capable of effectively addressing the thermal limitation and voltage stability issues of the system. Further, a battery is added to the UPFC to provide grid energy storage. Cost saving measures through controller design are also proposed and implemented. This work demonstrates that a UPFC can be an effective solution to typical problems (such as thermal and voltage constraints) faced by a transmission system. A UPFC with grid storage can also provide an alternative to building costly transmission lines or generation by enhancing reliability, reducing demand on generation cause by system peaks, smoothing intermittent generation, etc.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.207
Threshold uncertainty score0.856

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.179
Teacher spread0.172 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueMspace (University of Manitoba)Same topicThermal Analysis in Power TransmissionFrench-language works237,207