MétaCan
Menu
Back to cohort
Record W7038756629

An infrared spectrometer based on a MEMS fresnel zone plate for measuring dissolved gases in high voltage equipment

2017· dissertation· en· W7038756629 on OpenAlexaboutno aff

Bibliographic record

VenueMspace (University of Manitoba) · 2017
Typedissertation
Languageen
FieldChemistry
TopicSpectroscopy and Laser Applications
Canadian institutionsnot available
Fundersnot available
KeywordsFresnel lensInfraredZone plateSpectrometerDetectorAperture (computer memory)Lens (geology)Fourier transform infrared spectroscopyInfrared detectorHigh voltage
DOInot available

Abstract

fetched live from OpenAlex

This thesis presents a unique design for an infrared spectrometer based on a MEMS Binary Fresnel Zone Plate for the purpose of assessing the health of oil-impregnated high voltage (HV) equipment. It does so by measuring dissolved gases within it. These gases include carbon monoxide, carbon dioxide, methane, ethane, ethylene, and acetylene. These gases are currently measured using numerous technologies such as gas combustion, gas chromatography, photoacoustic spectroscopy, and FTIR spectroscopy. Each of these technologies have their advantages and disadvantages. The design presented in this thesis consists of an analysis of how the various Binary Zone Plate parameters affect its spectral resolution and transmission efficiency. Simulations show that increasing the number of zones and the focal length, as well as decreasing the aperture diameter, increases the spectral resolution of the spectrometer. Simulations also show that transmission efficiency is proportional to the number of zones and the aperture diameter. This thesis presents a theoretical argument for how one zone plate lens can be used to measure all dissolved gases present in HV equipment. Lenses for the visible and infrared ranges were fabricated in the University of Manitoba NSFL Cleanroom. The lenses were then tested in an optical setup. The results show that the visible light experiments were successful in achieving appropriate spectral discrimination by changing the distance between the aperture and the lens. The results from the infrared experiment show that a detector was able to discriminate between full and no incident radiation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.427
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.240
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueMspace (University of Manitoba)Same topicSpectroscopy and Laser ApplicationsFrench-language works237,207