MétaCan
Menu
Back to cohort
Record W7061520659

Pressurized liquid extraction (PLE) and liquid chromatography – tandem mass spectrometry (LC/MS/MS) for determination of Bisphenol A, Octylphenol and Nonylphenol in infant formulas.

2009· article· en· W7061520659 on OpenAlexaboutno aff

Bibliographic record

VenueUnicam Scientific Publications (University of Camerino) · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicMagnetic confinement fusion research
Canadian institutionsnot available
Fundersnot available
KeywordsBisphenol ANonylphenolExtraction (chemistry)Endocrine disruptorElectrospray ionizationLiquid chromatography–mass spectrometrySample preparationParabenSolid phase extractionMass spectrometry
DOInot available

Abstract

fetched live from OpenAlex

During the last decade there has been a worldwide scientific and public discussion about the potential consequences of long-term dietary exposure to endocrine disrupters. Bisphenol A (BPA) is a substance widely used for the manufacture of polycarbonate plastics and epoxy resins, which are used in plastic food containers, such as baby bottles. Nonylphenol (NP) and Octylphenol (OP) are intermediates to produce anionic and non-ion surfactants and are environmental contaminants [1].
\nSome recent reports determined the occurrence of these endocrine disruptor compounds in foods from different markets or containers; also, studies with the migration of BPA from baby bottles are available [2]. In April 2008, Health Canada released its Draft Screening Assessment for BPA, which concluded that the chemical may pose some risk to infants and proposed classifying the chemical as “toxic” to human health and environment. 
\n
\nThe aim of this work was to develop a new rapid, sensitive and reproducible analytical strategy for determining BPA, OP and NP content in powdered infant formulas using pressurized liquid extraction (PLE) and liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a triple quadrupole (QqQ) mass analyzer.
\nFor the extraction of the sample a comparative study was carried out using as dispersing agent C18 powder, and testing various solvents as dicloromethane, acetone, hexane, methanol, acetonitrile, and the mixture of them.
\nThe separation was carried out on a reverse phase C18 column using as mobile phase methanol/acetonitrile/water containing 0.1% ammonia. LC/MS/MS studies were performed using a QqQ equipped with an electrospray ionization (ESI) source operating in negative mode. Calibration curves, calculated in the range 0.05-5 g ml-1, showed excellent linearity (r2>0.998). The recoveries ranged from 63 to 91% with an RSD < 12%; limits of quantification (LOQs) were in the range 0.5-2.5 ng ml-1. 
\nPLE coupled with LC/ESI/MS/MS enables rapid and accurate determination of BPA, NP and OP in infant formulas. 
\n
\n[1] B. Shao et al. Food Chem., 2007, 105, 1236.
\n[2] N.C. Maragou et al. Food Addit. Contam., 2008, 25, 373.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.665
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.244
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueUnicam Scientific Publications (University of Camerino)Same topicMagnetic confinement fusion researchFrench-language works237,207