MétaCan
Menu
Back to cohort
Record W7111847039

Visual Performance and Refractive Stability of Clareon® Monofocal Intraocular Lens Implanted with an Automated Delivery System

2025· article· en· W7111847039 on OpenAlexaboutno aff

Bibliographic record

VenueDove Medical Press (Taylor and Francis Group) · 2025
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsnot available
Fundersnot available
KeywordsCorneal topographyIntraocular lensAstigmatismVisual acuityDelivery systemCataract surgeryIntraocular pressure
DOInot available

Abstract

fetched live from OpenAlex

Edward Tran,1,2 Nirmit Shah,2,3 Sandra Caballero Ortiz,2 Angela Kyveris,2 Graham Berg,2 Toby Chan2,4 1Schulich School of Medicine, University of Western Ontario, London, ON, Canada; 2Ocular Health Centre, Kitchener, ON, Canada; 3Melbourne Medical School, University of Melbourne, VIC, Australia; 4Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, CanadaCorrespondence: Edward Tran, Ocular Health Centre, 31 Kingsbury Dr Unit #501, Kitchener, ON, N2A 0K5, Canada, Email etran43@uwo.caPurpose: To evaluate the visual performance, refractive stability, and glistening-free clarity of the Clareon® monofocal intraocular lens (IOL) implanted using the AutonoMe® automated delivery system in a real-world North American setting.Patients and Methods: A prospective, single-arm study was conducted at a single Canadian site involving 46 patients, or 85 eyes, undergoing cataract surgery with Clareon® IOL implantation. Eligible participants were ≥ 22 years old with best-corrected distance visual acuity (BCDVA) of 0.3 logMAR or worse, targeted for emmetropia, and had < 1.0 D of preoperative astigmatism. Exclusion criteria included retinal disease, glaucoma, amblyopia, corneal pathology, and prior intraocular or corneal surgery. Manifest refraction, uncorrected (UDVA), best-corrected (BCDVA), and low-contrast visual acuity (LCVA) were assessed at 1, 3, and 12 months postoperatively. Glistenings were graded using the Miyata scale at 3 and 12 months.Results: No statistically significant changes were observed in manifest refraction, UDVA, or BCDVA between 1 and 3 months (p > 0.05). At 3 months, the mean spherical equivalent was +0.09 D, with low residual astigmatism (– 0.33 D). Mean logMAR UDVA and BCDVA were 0.13 and 0.02, respectively. LCVA was 0.04 logMAR. No glistenings were observed at either 3 or 12 months in any patient. Refractive and visual outcomes remained stable over time, with no device-related complications reported.Conclusion: The Clareon® IOL demonstrated excellent refractive accuracy, stable visual performance, and sustained optical clarity with no glistenings up to one year postoperatively. Its compatibility with the AutonoMe® delivery system supports its utility as a reliable option for cataract surgery.Keywords: cataract surgery, Clareon, monofocal intraocular lens, automated delivery system, surgical outcomes

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.045
Threshold uncertainty score0.090

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.324
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueDove Medical Press (Taylor and Francis Group)Same topicOphthalmology and Visual Impairment StudiesFrench-language works237,207