MétaCan
Menu
← Back to cohort
Record W7114775055 · doi:10.3389/fauot.2025.1714575

Clinical evaluation of DSL-BCD fittings: assessing output-to-targets for percutaneous bone conduction devices in practice

2025· article· en· W7114775055 on OpenAlexaff

Bibliographic record

VenueFrontiers in Audiology and Otology · 2025
Typearticle
Languageen
FieldNeuroscience
TopicHearing Loss and Rehabilitation
Canadian institutionsWestern UniversityMisericordia Community HospitalUniversity of Alberta
Fundersnot available
KeywordsStandard deviationPercutaneousBone conductionIntelligibility (philosophy)Hearing aidMean squared errorClinical PracticeHearing loss

Abstract

fetched live from OpenAlex

Objectives Objective measurements and prescriptive formulas for air-conduction hearing aids have been discussed extensively in the literature. In contrast, the application of objective verification tools such as clinical skull-simulators in the bone-conduction amplification literature is still emerging. This approach offers a critical step toward understanding the variability in percutaneous bone-conduction hearing devices (BCD) output on a larger scale. Our study aims to quantify this variability using skull-simulator measurements of percutaneous BCD users, thereby generating accuracy description of the range of outputs normally fitted in a clinical context. Design A cross-sectional retrospective study was conducted, analyzing skull-simulator measurements from routine audiology appointments of 79 adult percutaneous BCD users fitted with the DSL-BCD v1.1 prescription procedure. We explored the relationship between in-situ bone-conduction hearing thresholds and frequency-specific and root mean square error (RMSE) deviations from targets, along with aided speech intelligibility index (SII) using linear regressions for standard speech signals. BCD skull-simulator measurements were conducted at the user's daily listening level. Results At a 65 dB SPL speech input, over 50% of participants showed output-to-target deviations within ±5 dB at all frequencies except 750, 6,000, and 8,000 Hz. Fittings generally fell below targets as in-situ bone-conduction thresholds worsened, with exceptions at 250 and 500 Hz showing the reverse trend. A significant correlation was observed between in-situ bone-conduction thresholds and aided SII across all input levels, indicating an expected decrease in aided SII with increased bone-conduction hearing loss. The RMSE was within 5 dB for 37% of participants, lower than reported in air-conduction hearing aid literature. Secondary analyses assessing BCD capabilities of matching targets following fine-tuning, without participants' involvement, indicated that a RMSE within 5 dB could be met in 79% of cases. Conclusions This study outlines the deviations in output-to-target and aided SII among adult percutaneous BCD users, offering clinicians a benchmark through 95% confidence interval regression models and in-situ threshold averages. This normative data is beneficial for fitting BCDs in users with elevated in-situ thresholds, reducing uncertainty about optimal fittings. Further research is necessary to elucidate the relationship between aided SII, output-to-target deviations, outcomes and preferences in percutaneous BCD wearers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.020
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.020
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.417
Teacher spread0.356 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueFrontiers in Audiology and Otology→Same topicHearing Loss and Rehabilitation→French-language works237,207→