Comparative evaluation of Silver Dioxide–Coated Stainless Steel Wire and Non Coated Stainless Steel Wire for Susceptibility to Corrosion: Protocol for an In Vitro Study (Preprint)

2025· article· en· W7117501590 on OpenAlexvenueno aff
Aishwarya R Atey, Rizwan Gilani, Shefali Singh, Abhijeet Kadam

Bibliographic record

VenueJMIR Research Protocols · 2025
Typearticle
Languageen
FieldMaterials Science
TopicCorrosion Behavior and Inhibition
Canadian institutionsnot available
Fundersnot available
KeywordsProtocol (science)Materials testingCorrosionAustenitic stainless steelWeldability

Abstract

fetched live from OpenAlex

Background: Stainless steel (SS) orthodontic archwires are widely used because of their mechanical properties, affordability, and biocompatibility; yet, prolonged intraoral exposure can cause electrochemical corrosion and release of metal ions (eg, Ni and Cr) that may affect clinical performance and patient safety. Surface coatings such as silver dioxide have been proposed to improve corrosion resistance, but comparative data for silver dioxide-coated versus uncoated SS orthodontic archwires across clinically relevant simulated oral environments are lacking. Objective: This study aimed to compare the corrosion susceptibility of silver dioxide-coated and noncoated 0.019"×0.025" SS orthodontic archwires in four simulated oral solutions by measuring electrochemical behavior, cumulative metal ion release, and mass lossthereby testing our null hypothesis (H₀) that no difference exists between coated and noncoated wires. Methods: This in vitro protocol uses 40 SS archwire specimens divided into two main groups (20 silver dioxide-coated, and 20 uncoated) and four immersion subgroups (n=5 per subgroup): (1) 0.9% NaCl, (2) phosphate-buffered solution acidified with lactic acid (pH ~6.75), (3) phosphate-buffered solution with 0.1 wt% NaF, and (4) phosphate-buffered solution with 0.1% w/v bovine serum albumin. Coatings will be deposited by radiofrequency magnetron sputtering to achieve a 15- to 20-nm silver oxide (Ag₂O/AgO) layer; coating quality will be verified through scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDS), and profilometry. Specimens will be incubated individually at 37 °C with orbital agitation; immersion solutions will be sampled at baseline, 14 days, and 28 days. The primary outcome is corrosion current density (Icorr, µA/cm²) from potentiodynamic polarization. Secondary outcomes include pitting potential (Epit, mV vs SCE), cumulative ion release (Ag, Ni, Cr, Fe; expressed µg/mm²) analyzed by inductively coupled plasma-optical emission spectrometry (ICP-OES) after acidification, percent weight loss normalized to surface area (mg/cm²), and SEM/EDS surface analyses. Electrochemical tests will follow a standardized three-electrode setup (SCE reference). Statistical analyses will be used to assess normality; we will use independent-samples tests or nonparametric equivalents for between-group comparisons and mixed-effects models for time-dependent measures. Tests were evaluated at α=.05, with effect sizes and 95% CIs reported throughout. Results: Institutional ethical approval was obtained in April 2024 (DMIHER(DU)/IEC/2024/253). Coating parameters and quality control procedures have been established, and 40 specimens have been prepared and characterized. Immersion and electrochemical experiments are scheduled between June and December 2025, followed by ICP-OES analysis and statistical evaluation, with study completion planned by December 2025. Conclusions: This protocol will generate comparative data on electrochemical corrosion, ion release, and material degradation of silver dioxide-coated versus uncoated SS orthodontic archwires under multiple simulated oral conditions. Our findings will inform the potential of silver dioxide coatings to enhance the durability and biocompatibility of orthodontic archwires and will guide future in vivo or clinical investigations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Protocol · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.276
GPT teacher head0.553
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreProtocol

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractno

Explore more

Same venueJMIR Research ProtocolsSame topicCorrosion Behavior and InhibitionFrench-language works237,207