Commissioning of Bilateral (Parallel Opposed) Extended Source-to-surface Distance Total Body Irradiation Technique and Its Long-term Stability

2025· article· en· W7117751502 on OpenAlexaff
T Ganesh, Biplab Sarkar, Anusheel Munshi, Bidhu Kalyan Mohanti, S. Venu Gopal, G Gulia, S. Roy, Harpreet Kaur, Satheeshkumar Anbazhagan, K Jassal, Sasikumar Rathinamuthu, U Giri, Sandeep Singh Dhilan, Vijendra Kumar, Pallab Sarkar

Bibliographic record

VenueJournal of Medical Physics · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsSaskatchewan Cancer Agency
Fundersnot available
KeywordsStability (learning theory)IrradiationProject commissioningTotal body irradiation

Abstract

fetched live from OpenAlex

Aim: This article describes the commissioning of a total body irradiation (TBI) technique using bilateral-parallel-opposed fields at extended source-to-surface distance (SSD). Material: The measurements are based on the actual patient treatment geometry, which requires the patient to be placed inside a Perspex box. The gaps between the patient and the walls of the Perspex box were filled with rice bags to achieve full scattering conditions. The TBI box's lateral separation can be adjusted to 42 cm, 52 cm, or 62 cm by inserting the removable side walls to either of the three pairs of slots. A Farmer chamber, inserted inside a water-equivalent plastic slab phantom placed under full scattering conditions, was used for depth dose and profile measurements. The extended SSD was 333.5 cm, and the available field size was 132 cm × 132 cm. For output measurement, dose-to-water calibration factors for 6 MV and 15 MV energies were derived for the extended SSD. Bilateral-opposed fields were measured at three different separations to calculate lateral tissue effects. Result: For the 6 MV and 15 MV beams at a 42 cm separation, the midline-to-surface dose ratios were 1:1.17 and 1:1.08, respectively. As the separation increased, this ratio increased faster for the 6 MV beam and slower for the 15 MV beam. For the end-to-end quality assurance test (monitor unit to dose verification), the noted deviations were - 2.16% for the 6 MV beam and - 1.27% for the 15 MV beam. Conclusion: This article presents the detailed commissioning and long-term stability of the extended SSD TBI technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.310
Teacher spread0.298 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207