MétaCan
Menu
Back to cohort
Record W71311430 · doi:10.1051/ject/200335128

Quality of Red Blood Cells Using Autotransfusion Devices: A Comparative Analysis

2003· article· en· W71311430 on OpenAlexaff
Cyril Serrick, Mary Scholz, Arthur Nascimento de Melo, Onkar Singh, D. Noël

Bibliographic record

VenueJournal of ExtraCorporeal Technology · 2003
Typearticle
Languageen
FieldMedicine
TopicBlood transfusion and management
Canadian institutionsTrillium Health Centre
Fundersnot available
KeywordsAutotransfusionHematocritPlateletCentrifugationHeparinRed blood cellBlood productSurgeryMedicineBlood transfusionChemistryBiomedical engineeringChromatographyImmunologyInternal medicine

Abstract

fetched live from OpenAlex

Cell salvage devices are routinely used to process and wash red blood cells (RBCs) shed during surgical interventions. Although the principle theory of cell saving is the same, the actual process to achieve this is very different from one device to another. The purpose of this study was to compare the quality of washed, concentrated RBC produced by five very different cell-saving devices, specifically the Cobe BRAT 2, Medtronic Sequestra 1000, Haemonetics Cell Saver 5, Medtronic Autolog, and the Fresenius CATS. Reservoir and washed red blood cells were analyzed for hematocrit (Hct), platelets (PLT), leukocytes (WBC), potassium (K+), heparin, plasma-free hemoglobin (PFH), RBC mass recovery and recovery rate. The Haemonetics and BRAT 2 had the highest RBC recovery. All devices adequately removed heparin and potassium. The Medtronic Autolog had the highest removal of platelets and PFH; whereas, the BRAT had the lowest. Although the Autolog had the highest leukocyte removal, leukocytes were not adequately washed out by any of the autotransfusion devices. In conclusion, although all cell-saving devices use the same theory of centrifugation, the actual quality of the washed RBC product differs widely from one device to another.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.089
Threshold uncertainty score0.561

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.064
GPT teacher head0.349
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations78
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ExtraCorporeal TechnologySame topicBlood transfusion and managementFrench-language works237,207