MétaCan
Menu
Back to cohort
Record W7131355915 · doi:10.3329/bjmp.v16i2.84809

Evaluation of a Miniature Ge-Doped Silica Optical Fiber Radioluminescence Dosimeter for Absolute Dose Measurement in a 6 MeV Electron Radiotherapy Beam

2025· article· W7131355915 on OpenAlexaff
M Abul Hasnat, Md Masud Alam, Bonganur Khan, M Rafiqul Islam, Priyanka Poddar, Fatema Tuz Zohra, Rayhan Alam, Ashrafun Nahar Monika, Shirin Akter, M M Ahasan, Md Mahfuzur Rahman, Md. Kabir Uddin Sikder, Rajada Khatun

Bibliographic record

VenueBangladesh Journal of Medical Physics · 2025
Typearticle
Language
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsAtomic Energy (Canada)
Fundersnot available
KeywordsRadioluminescenceDosimeterDosimetryCalibrationOptical fiberIonization chamberDose profileDetectorLinear particle accelerator

Abstract

fetched live from OpenAlex

In radiotherapy, absolute dosimetry has traditionally relied on ionization chambers, which provide high accuracy but are relatively bulky and expensive. But in contrast, miniaturized radioluminescence (RL) detectors present a promising alternative, offering compact size, real-time readout, and reduced cost. This study aims to evaluate the dosimetric performance of a Ge-doped silica optical fiber ((SiO2:Ge), with dimensions of 1 mm in diameter and 1 mm in length, as a radioluminescence (RL) detector for absolute dose measurements in a 6 MeV electron beam generated by a Varian Clinac-iX linear accelerator. A SiO2:Ge was coupled to a 1 mm silica optical fiber and positioned at a depth of 2.4 cm in a water-equivalent bolus, corresponding to the R50 for 6 MeV electrons, with a source-to-surface distance (SSD) of 100 cm. Irradiations were delivered using a Varian Clinac-iX at a dose rate of 400 MU/min under controlled room conditions (20°C, 101320 Pa). The RL signal was transmitted via the optical fiber to a myDoz® RL/OSL dosimetry system, which recorded the emitted photon counts. Calibration was carried out with reference doses of 1 Gy and 5 Gy, and the response was subsequently validated at 2 Gy. With the SiO2:Ge in place, photon counts of 22340 and 111413 were recorded at 1 Gy and 5 Gy, respectively, while corresponding measurements without the crystal yielded 20017 and 99832 counts. Linear calibration predicted counts of 44608 (with sample) and 39,971 (without sample) for a 2 Gy exposure. The experimentally measured values of 44539 and 39940 differed from the predictions by less than 0.3%, thereby confirming the excellent linearity of the detector response. This 1 mm × 1 mm Ge-doped silica optical fiber RL dosimeter demonstrated a highly accurate and linear dose response in 6 MeV electron beam irradiation. This study reveals that its sensitive volume is smaller than that of conventional ionization chambers, the detector presents a promising, low-cost approach for small-field and in vivo dosimetry. Ban. J. Med. Phys., Vol -16, Issue -2, 2025 : 73-76

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.850
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0080.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.337
Teacher spread0.310 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueBangladesh Journal of Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207