MétaCan
Menu
Back to cohort
Record W7132504725

СРАВНЕНИЕ НА КОМПЮТЪРИЗИРАНИ СПРЯМО КОНВЕНЦИОНАЛНИ УПРАЖНЕНИЯ И УСТАНОВЯВАНЕ НА ТЯХНАТА ОПТИМАЛНА ЧЕСТОТА, ИНТЕНЗИВНОСТ И ПРОДЪЛЖИТЕЛНОСТ ПРИ АРТРОПЛАСТИКА НА ТАЗОБЕДРЕНАТА СТАВА

2023· dissertation· W7132504725 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueBulgarian Portal for Open Science · 2023
Typedissertation
Language
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsTest (biology)ArthritisJoint (building)Rheumatoid arthritis
DOInot available

Abstract

fetched live from OpenAlex

В резултат на ескалиращото нарастване на броя на хората, страдащи от остеоартрит на тазобедрената става(ТБС), дължащо се на застаряването на популацията и увеличаващия се брой на хора с наднормено тегло и заседнал начин на живот в световен мащаб, броя на извършените артропластики на ТБС се увеличават с бърз темп.С увеличение на нуждата от тазобедрено ендопротезиране, нараства нуждата от следоперативно възстановяване. Целта на настоящия труд е да се сравни ефективността на компютъризирани спрямо ковенционални лечебни упражнения в България, като се установи тяхната оптимална честота, продължителност и интензивност при пациенти след артропластика на ТБС. Задачите: Да се сравни ефективността на компютъризираните спрямо конвенционалните упражнения в ранната рехабилитация при пациенти след артропластика на ТБС чрез сравнителен анализ на резултатите от мануално мускулно тестуване (ММТ), ъглометрия, Western Ontario and McMaster Universities Arthritis Index, Harrison hip score test и тестове за походка, тъй като липсват аналогични проучвания в България и да се установи оптималната честота, продължителност и интензивност на компютъризираните и конвенционалните лечебни упражнения в ранната рехабилитация при пациенти след артропластика на тазобедрената става, тъй като липсват международни проучвания върху тези най-важни кинезитерапевтични параметри. Материали и Методи: Изследването обхваща общо 110 пациенти, всичките оперирани от един и същи ортопед, с един и същ оперативен достъп (лате

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.006
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Science and technology studies, Scholarly communication, Open science, Research integrity, Insufficient payload (model declined to judge)
Consensus categoriesMeta-epidemiology (narrow), Science and technology studies, Research integrity, Insufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.391
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0120.006
Meta-epidemiology (narrow)0.0040.004
Meta-epidemiology (broad)0.0060.002
Bibliometrics0.0030.007
Science and technology studies0.0070.005
Scholarly communication0.0050.005
Open science0.0120.004
Research integrity0.0020.004
Insufficient payload (model declined to judge)0.0120.006

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.366
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it