Bibliographic record
Abstract
Relatively high dose to the lung due to radon and its progeny in the normal natural environment was recognized a few decades ago. However, the dose had not been paid much attention since its dose was localized only in the lung. In late seventies radon became worldwide concern due to the introduction of the dose unit of effective dose equivalent (effective dose in present terminology) by ICRP Publ. 26. In the early eighties UNSCEAR requested every member states to carry out nation-wide indoor radon survey for the population dose estimation in the world. Only limited number of countries at that time had completed the nation-wide indoor radon survey, such as Canada. In accordance with the UNSCEAR's request a radon survey was conducted by our group in Japan during 1985 and 1991. A robust, non-expensive and reliable passive detector was searched for the use of our nation-wide survey. Karlsruhe type passive radon detector was then chosen for the survey. The detector film was polycarbonate and its treatment after the exposure was the electrochemical etching. Using this method more than 7,000 houses throughout Japan were measured to obtain annual average indoor radon concentration. The survey demonstrated that the percentage of houses having high radon concentration more than 150 Bq m-3 was only 0.4% of the house stock in Japan. We additionally found Karlsruhe type passive radon detector had higher air exchange rate than expected and showed radon concentrations affected by thoron. To solve the interference of thoron in radon measurement a new passive detector (UFO type) was designed to discriminate radon from thoron. The second nation-wide survey using the UFO type detector was conducted during 1992 and 1996 with a relatively small scale. After the finalization of our indoor radon surveys, all our devices related to the passive radon measurements were donated to Vinca in November 2002 wishing the active usage of the tools in this region.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".