MétaCan
Menu
← Back to cohort
Record W7162030773 · doi:10.82308/2899

Electron arc therapy using an Electa SL-25 linear accelerator at Maisonneuve-Rosemont Hospital (Montreal, Canada)

2006· dissertation· en· W7162030773 on OpenAlexaboutno aff
Caroline. Duchesne

Bibliographic record

Venuenot available
Typedissertation
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
Fundersnot available
KeywordsMonitor unitLinear particle acceleratorRADIUSArc (geometry)DosimetryCathode rayRadiation therapyRadius of curvatureBeam (structure)

Abstract

fetched live from OpenAlex

Electron arc therapy is a special radiotherapeutic technique using a rotational electron beam in the treatment of large superficial tumours following curved surfaces. In those cases, arc therapy offers the best way to optimize dose uniformity while sparing healthy tissues and critical organs. The use of this technique overcomes under or over dosage problems caused by field junctions. However, electron arc therapy presents important challenges in terms of dosimetry and treatment planning. Clinical implementation of electron arc therapy requires the study of many parameters of influence such as the radius of curvature of the treated surface, the width of the treatment field, the total angle of irradiation and the beam energy. Monitor unit calculation to deliver prescribed dose is a very critical topic and, in general, requires acquisition of a large amount of measured dosimetric data. This project concerns the clinical implementation of electron arc therapy using an Elekta SL-25 linear accelerator in the radiation oncology department of the Maisonneuve-Rosemont Hospital (Montreal, Canada). Firstly, the objective of the study is to observe the influence of the radius of curvature, the total arc angle and the field width on the following dosimetric parameters: depth of maximum dose, isodose distributions and electron arc beam output at the depth of maximum dose. Secondly, for our particular setup, the goal is to develop a simple monitor unit calculation method, based on an analytical model fitted through measured dosimetric data covering a large range of possible clinical situations. In order to achieve these goals, electron arc irradiations were performed on cylindrical acrylic phantoms of different radii, successively varying the total arc angle and the field width at isocentre. Results obtained with thermoluminescent dosimeters show a minor impact of the radius of curvature variation on the percent depth dose curves. However, they show a significant impact on the beam output. It was also observed that the total arc angle influences the dose at the depth of maximum dose only up to a limit angle value, different for each radius of curvature. Finally, the field width at isocentre has an impact on the beam output as well as on the bremsstrahlung contribution at the isocentre. Concerning the monitor unit calculation, a seven parameter analytical model fitted through measured data was obtained using Origin 7 software. A relationship giving the beam output as a function of the radius of curvature and the total arc angle was found. The field width was not included in the model, but will be part of further investigation before clinical implementation. As future work, dosimetric measurements with other energies should be carried on, mainly to be able to cover a wider range of clinical cases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.842
Threshold uncertainty score0.314

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0130.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.272
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2006
Admission routes1
Has abstractyes

Explore more

Same topicAdvanced Radiotherapy Techniques→French-language works237,207→