MétaCan
Menu
Back to cohort
Record W81030650 · doi:10.1093/jaoac/92.1.2

Determination of Oxytetracycline/Oxytetracycline Hydrochloride in Animal Feed, Fish Feed, and Veterinary Medicinal Products by Liquid Chromatography with Fluorescence Detection: Collaborative Study

2009· article· en· W81030650 on OpenAlexaboutno aff
Nancy Thiex, Richard D Larson, Mohamed S. Ahmed, Klaus Albert, Yu.Yu. Babin, Helen Campbell, Malcolm Campbell, A. Deatley, S. Eigen, Kristen Elson, Matthew Farrow, M Firman, J Jamieson, D Jobin, J Kibbey, Patrick Kirby, Richard C. Larson, David B. Marshall, Jennifer Mathis, K. T. McManus, L Menefee, Lauren T. Olson, S Panagiotis, Jeremy M. Raines, David W. Rowe, Jane Sabbatini, Dipti Singh, Catherine Smith, M A Stenske, Hans van Rhijn, Susan M. Williams

Bibliographic record

VenueJournal of AOAC International · 2009
Typearticle
Languageen
FieldEnvironmental Science
TopicPharmaceutical and Antibiotic Environmental Impacts
Canadian institutionsnot available
Fundersnot available
KeywordsOxytetracyclineChromatographyVeterinary DrugsChemistryRepeatabilityAnimal feedFish <Actinopterygii>Veterinary medicineHigh-performance liquid chromatographyFood scienceBiologyAntibioticsFisheryMedicineBiochemistry

Abstract

fetched live from OpenAlex

A method for determining oxytetracycline (OTC) in animal feed, fish feed, and veterinary medicinal products at medicated use and contamination levels was collaboratively studied. The method is applicable to the analysis of animal feeds and mineral premixes containing levels > or =2 mg/kg, and fish feed containing levels > or =10 mg/kg. Oxytetracycline hydrochloride (OTC.HCI) is extracted from ground feed material in acid-methanol solution using mechanical agitation. After centrifugation for 5 min at 1230 x g, an aliquot of the extract is diluted with water andlor acid-methanol so that the concentration of OTC.HCI is approximately the same as that in the working standard, and the solutions contain at least 50% water. Injectable veterinary medicinal materials (also called animal remedy materials) are diluted with water andlor extractant to reach the target concentration. The extracts are filtered and analyzed by reversed-phase liquid chromatography with fluorescence detection with excitation at 390 nm and emission at 512 nm. Twenty-eight test samples of medicated feeds, supplements, and drug premixes, including 4 test samples for trace-level analysis, were sent to 17 collaborators in Canada, The Netherlands, and the United States. Results were received from 11 laboratories. The RSDr values (within-laboratory repeatability) ranged from 1.26 to 9.21%; RSDR values (among-laboratory reproducibility) ranged from 2.14 to 12.9%, and HorRat values ranged from 0.54 to 3.02. It is recommended that this method be adopted AOAC Official First Action.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.631
Threshold uncertainty score0.547

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.280
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueJournal of AOAC InternationalSame topicPharmaceutical and Antibiotic Environmental ImpactsFrench-language works237,207