Frangibility of airport approach lighting towers
Notice bibliographique
Résumé
A series of full-scale impact tests on approach lighting towers, used at Canadian airports, was conducted to provide information on tower response. These data were necessary for the development of simplified requirements and test methods for the design of frangible structures, which will minimize the impact hazard to aircraft. A total of 48 tests were completed which included striking the tower triangular cross-section at both the apex and on the side at high, medium and low impact speeds (140, 80 and 50 Ian/h). High-speed video cameras were used during test program to record the impact sequence, the mode of failure and the contact time between the impactor and the tower. The influence of impact speed on the maximum impact force, energy to maximum force and energy over the contact period were key parameters measured in order to define the requirements for frangibility. A discrete model to simulate the impact of.the tower was developed using finite element analysis (FEA). The results obtained from this model were compared to the full-scale test results to validate the accuracy of the model. In addition, the tower dynamic behavior was compared to the visual data obtained from the high-speed video cameras to confirm failure mode predictions.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».