Characterization of a condensed‐phase membrane introduction mass spectrometry (CP‐MIMS) interface using a methanol acceptor phase coupled with electrospray ionization for the continuous on‐line quantitation of polar, low‐volatility analytes at trace levels in complex aqueous samples
Bibliographic record
Abstract
We report the development and application of a capillary hollow fibre membrane interface using methanol as an acceptor phase to deliver target analytes to an electrospray ionization source and a triple quadrupole mass spectrometer. Superior fluid handling systems lead to greater signal stability and membrane integrity for the continuous on-line monitoring of polar and charged analytes in complex aqueous samples with detection limits in the parts-per-trillion to parts-per-billion range. The system can be operated in either a continuous flow or a stopped acceptor flow mode - the latter giving rise to greater sensitivity. We report detection limits, enrichment factors and signal response times for selected analytes with polydimethylsiloxane and Nafion® polymer membrane interfaces. In addition, we demonstrate the use of this interface to detect pharmaceuticals and other contaminants in natural water and artificial urine. The improved sensitivity and analytical response times of our CP-MIMS system make it possible to continuously monitor dynamic chemical systems with temporal resolutions on the order of minutes. Presented is a comparison of the performance of CP-MIMS versus direct infusion electrospray ionization, demonstrating the potential advantages over direct infusion for trace analyte measurements in complex, high ionic strength samples. Furthermore, by continuously flowing a reaction mixture in a closed loop over the interface, we demonstrate the use of the system as an in situ reaction-monitoring platform for the chlorination of a model organic compound in aqueous solution.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.003 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".