MétaCan
Menu
Back to cohort
Record W1594942802 · doi:10.1155/2006/715459

Hydrogen Breath Test for Diagnosis of Lactose Malabsorption: The Importance of Timing and the Number of Breath Samples

2006· article· en· W1594942802 on OpenAlexvenueno aff
Mauro Di Camillo, Vanessa Marinaro, Fiorenza Argnani, Tiziana Foglietta, Piero Vernia

Bibliographic record

VenueCanadian Journal of Gastroenterology · 2006
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicDigestive system and related health
Canadian institutionsnot available
Fundersnot available
KeywordsMalabsorptionLactoseHydrogen breath testBreath testGastroenterologyHydrogenMedicineInternal medicineChemistryBiochemistryOrganic chemistry

Abstract

fetched live from OpenAlex

BACKGROUND: The hydrogen breath test (H(2)BT) is the most widely used procedure in the diagnostic workup of lactose malabsorption and lactose intolerance. AIM: To establish whether a simplified two- or three-sample test may reduce time, costs and staff resources without reducing the sensitivity of the procedure. PATIENTS AND METHODS: Data from 1,112 patients (292 men, 820 women) with a positive 4 h, nine-sample H(2)BT were retrospectively analyzed. Patients were stratified according to the degree of lactose malabsorption, the occurrence and type of symptoms. Loss of sensitivity in the procedure was evaluated taking into account two-sample tests (0 min and 120 min or 0 min and 210 min) or three-sample tests (0 min, 120 min and 180 min or 0 min, 120 min and 210 min). RESULTS: Using a two-sample test (0 min and 120 min or 0 min and 210 min) the false-negative rate was 33.4% and 22.7%, respectively. With a three-sample test (0 min, 120 min and 180 min or 0 min, 120 min or 210 min), lactose malabsorption was diagnosed in 91.2% (1,014 of 1,112) patients and in 96.1% (1,068 of 1,112) patients, respectively. Of 594 patients with abdominal symptoms, 158 (26.6%) and 73 (12.2%) would have false-negative results with 0 min and 120 min or 0 min and 210 min two-sample tests, respectively. The three-sample tests, 0 min, 120 min and 180 min or 0 min, 120 min and 210 min, have a false-negative rate of 5.9% and 2.1%, respectively. CONCLUSIONS: A three-sample H(2)BT is time- and cost-sparing without significant loss of sensitivity for the diagnosis both of lactose malabsorption and lactose intolerance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.013
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.239
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Journal of GastroenterologySame topicDigestive system and related healthFrench-language works237,207