MétaCan
Menu
Back to cohort
Record W1842969195 · doi:10.1186/s12947-015-0023-6

Grading diastolic function by echocardiography: hemodynamic validation of existing guidelines

2015· article· en· W1842969195 on OpenAlexaff
Andrew Grant, Kazuaki Negishi, Tomoko Negishi, Patrick Collier, Samir Kapadia, James D. Thomas, Thomas H. Marwick, Brian P. Griffin, Zoran Popović

Bibliographic record

VenueCardiovascular Ultrasound · 2015
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Function and Risk Factors
Canadian institutionsLibin Cardiovascular Institute of AlbertaUniversity of Calgary
Fundersnot available
KeywordsMedicineCardiologyInternal medicinePreloadHemodynamicsEjection fractionDiastoleInterquartile rangeSinus rhythmBlood pressureHeart failureAtrial fibrillation

Abstract

fetched live from OpenAlex

BACKGROUND: While echocardiographic grading of left ventricular (LV) diastolic dysfunction (DD) is used every day, the relationship between echocardiographic DD grade and hemodynamic abnormalities is uncertain. METHODS: We identified 460 consecutive patients who underwent transthoracic echocardiography within 24 h of elective left heart catheterization and had: normal sinus rhythm, no confounding structural heart disease, no change in medications between catheterization and echo, and complete echocardiographic data. Patients were grouped based on echocardiographic DD grade. Hemodynamic tracings were used to determine time constant of isovolumic pressure decay (Tau), LV end-diastolic pressure (LVEDP) and end-diastolic volume index at a pressure of 20 mmHg (EDVi20). RESULTS: Normal diastolic function was found in 55 (12.0%) patients, while 132 (28.7%) patients had grade 1, 156 (33.9%) grade 2 and 117 (25.4%) grade 3 DD. The median value for Tau was 46.9 ms for the overall population (interquartile range 38.6-58.1 ms), with a prevalence of a prolonged Tau (>48 ms) of 47.5%. While there was an association between DD grade and Tau (p = 0.003), LV dysfunction (ejection fraction <50%) was more strongly associated with increased Tau (p < 0.001) than was DD grade (p = 0.19). There was also an association between DD grade and LVEDP (p < 0.001), with both LV dysfunction (p = 0.029) and DD grade (p < 0.001) independently associated with LVEDP. Calculated EDVi20 was related to DD grade, but this relationship was driven by findings of paradoxically increased compliance in patients with severe DD. CONCLUSIONS: Although echocardiographic grading of DD was related to invasive hemodynamics in this population, the relationship was modest.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.019
metaresearch head score (Gemma)0.061
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: Methods · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.981
Threshold uncertainty score0.102

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0190.061
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0030.002
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.070
GPT teacher head0.300
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designObservational
DomainMethods
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueCardiovascular UltrasoundSame topicCardiovascular Function and Risk FactorsFrench-language works237,207