MétaCan
Menu
Back to cohort
Record W2011106803 · doi:10.1213/ane.0b013e31819cd8a3

Surface Anatomy as a Guide to Vertebral Level for Thoracic Epidural Placement

2009· article· en· W2011106803 on OpenAlexaff
Desiree A. Teoh, Kristi L. Santosham, Carmen C. Lydell, Dean F. Smith, Michael Beriault

Bibliographic record

VenueAnesthesia & Analgesia · 2009
Typearticle
Languageen
FieldMedicine
TopicAnesthesia and Pain Management
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsMedicineSpinous processAnatomical landmarkSurface anatomyThoracic vertebraeVertebraRadiographyBody mass indexLandmarkVisual analogue scaleAnatomyOrthodonticsSurgeryLumbarLumbar vertebraeInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Precise placement of thoracic epidural catheters is required to optimize postoperative analgesia and minimize adverse effects. Previous research demonstrated that anesthesiologists are inaccurate when using surface anatomy to locate vertebral levels. In this study, we compared the accuracy of two different landmarks to identify the seventh thoracic (T7) spinous process. METHODS: Two-hundred-ten patients referred for chest radiography were randomized to two groups. With patients in the anatomic (upright) position, one investigator identified and placed a radioopaque marker over the presumed T7 spinous process using either the vertebra prominens (C7) or the inferior scapular tip as a surface landmark. A radiologist, blinded to the identification technique, reported the spinous process corresponding to the radioopaque label. Marker positions were then compared using the Fisher's exact test. The influence of patient characteristics (age, gender, Body Mass Index [BMI], and height and weight) on accuracy was also examined. RESULTS: Patient characteristics were similar between groups. The T7 spinous process was identified correctly 29% of the time with the C7 landmark and 10% of the time with the scapular landmark (P < 0.001). Accuracy improved for T7 +/- 1 level to 78% and 42%, respectively (P = 5.84 x 10(-8)). Errors were more common in the caudal direction (i.e., T8 or T9 identified). The C7 landmark was more accurate among those with a BMI <25 (P = 6.51 x 10(-5)). In those with a BMI >or=25, both landmarking methods were frequently inaccurate (P = 0.312). CONCLUSIONS: For patients with a BMI <25, the T7 spinous process can be reliably identified to within one interspace in 78% of patients using the C7 (vertebra prominens) surface landmark. Neither the vertebra prominens nor the tip of scapula is a reliable landmark to identify T7 in patients with a BMI >or=25.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.219
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.347
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueAnesthesia & AnalgesiaSame topicAnesthesia and Pain ManagementFrench-language works237,207