MétaCan
Menu
Back to cohort
Record W2046185967 · doi:10.1039/b412078g

Quantitative determination of hexamethylene diisocyanate (HDI), 2,4-toluene diisocyanate (2,4-TDI) and 2,6-toluene diisocyanate (2,6-TDI) monomers at ppt levels in air by alkaline adduct coordination ionspray tandem mass spectrometry

2005· article· en· W2046185967 on OpenAlexaff
Sébastien Gagné, Jacques Lesage, Claude Ostiguy, Yves Cloutier, Huu Van Tra

Bibliographic record

VenueJournal of Environmental Monitoring · 2005
Typearticle
Languageen
FieldMedicine
TopicOccupational exposure and asthma
Canadian institutionsInstitut de Recherche Robert-Sauvé en Santé et en Sécurité du TravailUniversité du Québec à Montréal
Fundersnot available
KeywordsToluene diisocyanateHexamethylene diisocyanateTolueneChemistryMonomerAdductPolymer chemistryPolyurethaneOrganic chemistryPolymer

Abstract

fetched live from OpenAlex

Occupational exposures to isocyanates can lead to occupational asthma. Once sensitized, some workers could react to isocyanate monomers at concentrations below 1% of the Permissible Exposure Limit of 5 ppb in air. Currently available methods are not sufficiently sensitive to adequately evaluate isocyanates present at these levels in workplace air. This article describes a novel method for isocyanate determination allowing the ultratrace quantification in workplace air of hexamethylene diisocyanate, 2,4-toluene diisocyanate and 2,6-toluene diisocyanate monomers. Sampling is performed during a complete workshift at a flow rate of 1 L min(-1) with a cassette containing a 1-(2-methoxyphenyl)piperazine-impregnated 25 mm filter. Analysis is performed using liquid chromatography hyphenated with coordination ionspray tandem mass spectrometry. The analytical method's linearity was measured for a concentration range varying from the limit of detection of 0.04-0.13 ng mL(-1), depending on the monomer, up to approximately 32 ng mL(-1) for every isocyanate monomer, all with correlation coefficients (R(2)) greater than 0.999. The analytical method's lower limit of quantification combined with an adapted sampling strategy allow the quantification of isocyanate monomers down to 0.04 ppt for an 8 h work shift when a lithium adduct is used, which is more than 300 times lower than the most sensitive method currently available. This novel method can be used to confirm the very low level of isocyanate monomers for the safe reassignment of sensitized workers and it is also useful for charting the isocyanate dispersion tail in workplace environments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.429
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.281
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Environmental MonitoringSame topicOccupational exposure and asthmaFrench-language works237,207