MétaCan
Menu
Back to cohort
Record W2049947295 · doi:10.1089/jamp.2011.0927

Comparison of ISO Standards for Device Performance; 20072 and 27427: A Critical Appraisal

2012· review· en· W2049947295 on OpenAlexaff
Ola Nerbrink, Jolyon P. Mitchell

Bibliographic record

VenueJournal of Aerosol Medicine and Pulmonary Drug Delivery · 2012
Typereview
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsTrudell Medical International (Canada)
Fundersnot available
KeywordsScope (computer science)Computer scienceProcess managementRisk analysis (engineering)Product (mathematics)European unionReliability engineeringSystems engineeringManufacturing engineeringBusinessEngineering

Abstract

fetched live from OpenAlex

Two separate international standards, ISO 20072:2009 and ISO 27427:2010, have recently been published that relate to the development and performance testing of oral inhaled products (OIPs). The scope of ISO 20072 encompasses all OIP forms except nebulizing systems, whereas ISO 27427 was developed specifically for this class of OIP. Compliance with these standards will likely be necessary for manufacturers seeking approval to market inhaler devices in the European Union (EU). Their adoption in the United States may take a considerable time, but the FDA has expressed support in general terms for the ISO process. Key aspects of both standards that are very different in style and content are identified and discussed from the perspective of a potential user. In the approach adopted by ISO 20072, a formalized risk assessment is undertaken as a key part of design verification, in order to develop the Device Functionality Profile (DFP) of the device. The DFP is subsequently verified by the System Verification Test (SVT), in which pharmacopeial test methods are used to evaluate in vitro performance of the device with a chosen drug product in a statistically robust manner. On the other hand, ISO 27427 adopts a more prescriptive approach that involves performance verification of the finished nebulizing system using 1% w/v salbutamol as the test formulation. Although ISO 27427 is currently undergoing revision, at present it is unclear whether the changes that are made will significantly alter its fundamentally different approach to device performance verification. A strong case can be made for a single OIP-wide ISO standard, based on the principles developed in ISO 20072 and that makes use of the well-understood and validated in vitro test procedures that are available or will shortly be available in the case of nebulizing systems, in the United States and European pharmacopeias.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.932
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0040.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.098
GPT teacher head0.433
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Aerosol Medicine and Pulmonary Drug DeliverySame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207