MétaCan
Menu
Back to cohort
Record W2128013045 · doi:10.1109/robot.2008.4543279

Bilateral telemanipulation of a flexible catheter in a constrained environment

2008· article· en· W2128013045 on OpenAlexaff
Jagadeesan Jayender, Mahdi Azizian, Rajni V. Patel

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicTeleoperation and Haptic Systems
Canadian institutionsWestern University
Fundersnot available
KeywordsCatheterTeleoperationComputer scienceFlexibility (engineering)KinematicsControl theory (sociology)TeleroboticsHaptic technologySimulationRobotControl engineeringSurgeryEngineeringControl (management)MedicineArtificial intelligenceMathematicsPhysics

Abstract

fetched live from OpenAlex

This paper describes some novel research results on bilateral teleoperation of a flexible catheter in a constrained environment. The dynamics of the catheter in a constrained environment is highly nonlinear and is affected by a large number of factors such as friction, flexibility of the catheter, force of insertion, shape and size of the catheter, etc. As a result, the distal end of the catheter almost never follows the actuated end of the catheter which could cause fatigue to the clinician/user attempting to insert the catheter in a blood vessel. In addition, there is a time delay of up to 0.8 second before the distal end of the catheter advances after the near end is actuated. This delay is sufficient to cause instability in the control loop. We have developed a teleoperation framework using wave variables to perform robot- assisted catheter insertion in a constrained environment while reflecting the forces at the tip of the catheter to the clinician. Experimental results showing the effect of different factors such as the velocity and stroke length of insertion on the delays introduced in control loop and errors between the master and slave position are included. To the best of our knowledge, this work is among the first to attempt to provide an understanding of the effects of various factors on the flexing of the catheter. In addition, master-slave insertion of a catheter instrumented with shape memory alloys (SMA) has also been performed and the results are included in this paper.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.191
Teacher spread0.169 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2008
Admission routes1
Has abstractyes

Explore more

Same topicTeleoperation and Haptic SystemsFrench-language works237,207