Retraction

2012· article· en· 1 citations· W2169359596 on OpenAlex· 10.1111/j.1751-553x.2012.01411.x

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Post-publication record

Nature
Retraction
Reason
Copyright Claims;Objections by Third Party;Removed;
Date
4/23/2012 0:00
Flagged by OpenAlex?
Yes

Source: Retraction Watch, joined by DOI. OpenAlex records retraction as is_retracted, a boolean over a state space with at least four values, so it cannot express an expression of concern, a correction or a reinstatement — it reports them as false, which reads as “fine”.

Abstract

INTRODUCTION: The Beckman Coulter DxH 300™ is a hematology analyzer that performs a CBC and 3-part WBC differential and incorporates new electronic, algorithm and mechanical design. METHODS: This instrument was compared with the predicate analyzer (Coulter(®) A(c) ·Tdiff2) and the larger format Coulter LH780 analyzer. Of interest were flagging rates, clinical sensitivity, and accuracy of the WBC in the presence of interfering particles. The total sample set (n = 404) consisted of morphologically normal and hematologically abnormal patients. RESULTS: Correlation of the DxH 300 with A(c) ·Tdiff2™ showed good agreement with all directly measured parameters. When compared with the LH780, WBC and platelets (PLT) counts showed good agreement with small biases. Importantly in the low range (PLT <50 × 10(9) /L), there was a small positive bias of only 2 × 10(9) /L PLT. Interfering particles did not affect the DxH 300 WBC count (P > 0.05) with strong correlations to the LH780 (r(2) values >0.95). Importantly, overall and specific flagging rates as well as false-negative and false-positive rates were significantly reduced on the DxH 300 compared with the A(c) ·Tdiff2 (27% and 41% reduction, respectively, P < 0.001). CONCLUSIONS: The DxH 300 offers significant improvement over the predicate Coulter analyzer in flagging rates and improved correlation with larger format analyzers for WBC and PLT counts. Reduced false negatives and false positives significantly improved sensitivity and specificity compared to the predicate analyzer. The 28% improvement in flagging efficiency together with numerous software and data handling enhancements should translate into reduced need to perform follow-up analysis on a significant number of samples.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
International Journal of Laboratory Hematology
Topic
Clinical Laboratory Practices and Quality Control
Field
Medicine
Canadian institutions
London Health Sciences Centre
Funders
Keywords
FlaggingHematology analyzerSpectrum analyzerFalse positive paradoxFalse positive rateMedicineNuclear medicineMathematicsAnalytical Chemistry (journal)StatisticsPathologyChromatographyOpticsPhysicsChemistry
Has abstract in OpenAlex
yes