Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient‐reported outcomes
Bibliographic record
Abstract
OBJECTIVES: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient-reported outcomes in implant dentistry. Focused questions on (a) short posterior dental implants (≤6 mm), (b) narrow diameter implants, (c) implant design (tapered compared to a non-tapered implant design), and (d) medication-related dental implant failures were addressed. MATERIALS AND METHODS: Four systematic reviews were prepared in advance of the Consensus Conference and were discussed among the participants of Group 1. Consensus statements, clinical recommendations, and recommendations for future research were based on structured group discussions until consensus was reached among the entire expert Group 1. The statements were then presented and accepted following further discussion and modifications as required by the plenary. RESULTS: Short implants (≤6 mm) revealed a survival rate ranging from 86.7% to 100%, whereas standard implant survival rate ranged from 95% to 100% with a follow-up from 1 to 5 years. Short implants demonstrated a higher variability and a higher Risk Ratio [RR: 1.24 (95% CI: 0.63, 2.44, p = 0.54)] for failure compared to standard implants. Narrow diameter implants (NDI) have been classified into three categories: Category 1: Implants with a diameter of <2.5 mm ("Mini-implants"); Category 2: Implants with a diameter of 2.5 mm to <3.3 mm; Category 3: Implants with a diameter of 3.3 mm to 3.5 mm. Mean survival rates were 94.7 ± 5%, 97.3 ± 5% and 97.7 ± 2.3% for category 1, 2 and 3. Tapered versus non-tapered implants demonstrated only insignificant differences regarding clinical, radiographic, and patient-reported outcomes. The intake of certain selective serotonin reuptake inhibitors and proton pump inhibitors is associated with a statistically significant increased implant failure rate. The intake of bisphosphonates related to the treatment of osteoporosis was not associated with an increased implant failure rate. CONCLUSIONS: It is concluded that short implants (≤6 mm) are a valid option in situations of reduced bone height to avoid possible morbidity associated with augmentation procedures; however, they reveal a higher variability and lower predictability in survival rates. Narrow diameter implants with diameters of 2.5 mm and more demonstrated no difference in implant survival rates compared to standard diameter implants. In contrast, it is concluded that narrow diameter implants with diameters of less than 2.5 mm exhibited lower survival rates compared to standard diameter implants. It is further concluded that there are no differences between tapered versus non-tapered dental implants. Certain medications such as selective serotonin reuptake inhibitors and proton pump inhibitors showed an association with a higher implant failure rate.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.007 | 0.006 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.004 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.001 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".