MétaCan
Menu
Back to cohort
Record W2902801798 · doi:10.1155/2018/9235023

Force Analysis and Evaluation of a Pelvic Support Walking Robot with Joint Compliance

2018· article· en· W2902801798 on OpenAlexaff
Jiancheng Ji, Shuai Guo, Fengfeng Xi

Bibliographic record

VenueJournal of Healthcare Engineering · 2018
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsToronto Metropolitan University
FundersScience and Technology Commission of Shanghai MunicipalityNational Natural Science Foundation of China
KeywordsKinematicsBracePhysical medicine and rehabilitationSimulationComputer sciencePelvisRobotGaitEngineeringMedicineArtificial intelligencePhysicsSurgeryStructural engineering

Abstract

fetched live from OpenAlex

The force analysis of a pelvic support walking robot with joint compliance is discussed in this paper. During gait training, pelvic motions of hemiplegic patients may be excessively large or out of control; however, restriction of pelvic motions is not likely to facilitate successful rehabilitation. A robot-assisted pelvic balance trainer (RAPBT) is proposed to help patients control the range of motion via force field, and force analysis is necessary for the control of the compliant joints. Thus, kinematic model and static model are developed to derive the Jacobian and the relation between the interaction forces and the pelvic movements, respectively. Since the joint compliance is realized through a nontorsional spring, a conventional (linear) Jacobian method and a piecewise linear method are derived to relate the interaction forces with the pelvis movements. Three preliminary experiments are carried out to evaluate the effectiveness of the proposed methods and the feasibility of the RAPBT. The experiment results indicate that the piecewise linear method is effective in the calculation of the interaction forces. Gait with pelvic brace strongly resembles free overground walking and partly decreases motion range via force field. The findings of this research demonstrate that the pelvic brace with joint compliance may provide effective interventions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.287
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Healthcare EngineeringSame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207