MétaCan
Menu
Back to cohort
Record W3013514696 · doi:10.4187/respcare.07412

Development of Quality Assurance and Quality Control Guidelines for Respiratory Oscillometry in Clinic Studies

2020· article· en· W3013514696 on OpenAlexaffabout
Joyce Wu, E. deHaas, Richard Nadj, Aloysius Brandon Cheung, Ronald J. Dandurand, Zoltán Hantos, Clodagh M. Ryan, Chung‐Wai Chow

Bibliographic record

VenueRespiratory Care · 2020
Typearticle
Languageen
FieldMedicine
TopicChronic Obstructive Pulmonary Disease (COPD) Research
Canadian institutionsMcGill University Health CentreUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineAuditQuality assurancePulmonary function testingChecklistTest (biology)Protocol (science)Medical physicsInternal medicinePathologyExternal quality assessment

Abstract

fetched live from OpenAlex

BACKGROUND: The guidelines to conduct and interpret conventional pulmonary function (PFT) tests are frequently reviewed and updated. However, the quality assurance and quality control (QA/QC) guidelines for respiratory oscillometry testing remain limited. QA/QC guidelines are essential for oscillometry to be used as a diagnostic pulmonary function test (PFT) in a clinical setting. METHODS: We developed a QA/QC protocol shortly after oscillometry was introduced in our laboratory as part of a clinical study. The first clinical study began after the research personnel completed 3 h of combined didactic and hands-on training and establishment of a standard operating protocol (SOP) for oscillometry testing. All oscillometry tests were conducted using the initial SOP protocol from October 17, 2017, to April 6, 2018. At this time, the first QA/QC audit took place, followed by revisions to the SOP, the addition of a QA/QC checklist, and the development of a 12-h training program. A second audit of oscillometry tests was conducted from April 9, 2018, to June 30, 2019. Both audits were completed by a registered cardiopulmonary technologist from the Toronto General Pulmonary Function Lab. RESULTS: The first audit evaluated 197 paired oscillometry-PFT tests and found 10 tests (5.08%) to be invalid, with a coefficient of variation > 15%. The second audit examined 1,930 paired oscillometry-PFT tests; only 3 tests (0.16%) were unacceptable, with a coefficient of variation > 15%. Improvement in QA/QC was significantly better compared to the first audit ( P < .001). CONCLUSIONS: Although oscillometry requires minimal subject cooperation, application of the principles that govern the conduct and application of a PFT are important for ensuring that oscillometry testing is performed according to acceptability and reproducibility. Specifically, the inclusion of a SOP, a proper training program, a QA/QC checklist, and regular audits with feedback are vital to ensure that oscillometry is conducted accurately and precisely.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.635
metaresearch head score (Gemma)0.594
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.635
Threshold uncertainty score0.450

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.6350.594
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0050.004
Bibliometrics0.0160.013
Science and technology studies0.0060.007
Scholarly communication0.0120.007
Open science0.0130.006
Research integrity0.0080.012
Insufficient payload (model declined to judge)0.0040.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.284
GPT teacher head0.484
Teacher spread0.200 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designNot applicable
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueRespiratory CareSame topicChronic Obstructive Pulmonary Disease (COPD) ResearchFrench-language works237,207