MétaCan
Menu
Back to cohort
Record W40400960 · doi:10.1155/2011/320904

Point-of-Care, Peer-Comparator Colonoscopy Practice Audit: The Canadian Association of Gastroenterology Quality Program – Endoscopy

2011· article· en· W40400960 on OpenAlexaffvenueabout
David Armstrong, Roger Hollingworth, Donald MacIntosh, Ying Chen, Sandra Daniels, Stuart Gittens, R. F. Bridges, Paul Sinclair, Catherine Dubé

Bibliographic record

VenueCanadian Journal of Gastroenterology · 2011
Typearticle
Languageen
FieldMedicine
TopicColorectal Cancer Screening and Detection
Canadian institutionsUniversity of CalgaryCanadian Association of GastroenterologyDalhousie UniversityCredit Valley HospitalMcMaster University
Fundersnot available
KeywordsColonoscopyMedicinePolypectomyEndoscopyWithdrawal timeIntubationSedationAuditObservational studyGeneral surgeryInternal medicineEmergency medicineColorectal cancerSurgeryCancer

Abstract

fetched live from OpenAlex

BACKGROUND: Point-of-care practice audits allow documentation of procedural outcomes to support quality improvement in endoscopic practice. OBJECTIVE: To evaluate a colonoscopists' practice audit tool that provides point-of-care data collection and peer-comparator feedback. METHODS: A prospective, observational colonoscopy practice audit was conducted in academic and community endoscopy units for unselected patients undergoing colonoscopy. Anonymized colonoscopist, patient and practice data were collected using touchscreen smartphones with automated data upload for data analysis and review by participants. The main outcome measures were the following colonoscopy quality indicators: colonoscope insertion and withdrawal times, bowel preparation quality, sedation, immediate complications and polypectomy, and biopsy rates. RESULTS: Over a span of 16 months, 62 endoscopists reported on 1279 colonoscopy procedures. The mean cecal intubation rate was 94.9% (10th centile 84.2%). The mean withdrawal time was 8.8 min and, for nonpolypectomy colonoscopies, 41.9% of colonoscopists reported a mean withdrawal time of less than 6 min. Polypectomy was performed in 37% of colonoscopies. Independent predictors of polypectomy included the following: endoscopy unit type, patient age, interval since previous colonoscopy, bowel preparation quality, stable inflammatory bowel disease, previous colon polyps and withdrawal time. Withdrawal times of less than 6 min were associated with lower polyp removal rates (mean difference -11.3% [95% CI -2.8% to -19.9%]; P=0.01). DISCUSSION: Cecal intubation rates exceeded 90% and polypectomy rates exceeded 30%, but withdrawal times were frequently shorter than recommended. There are marked practice variations consistent with previous observations. CONCLUSION: Real-time, point-of-care practice audits with prompt, confidential access to outcome data provide a basis for targeted educational programs to improve quality in colonoscopy practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.689
Threshold uncertainty score0.753

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.308
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2011
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of GastroenterologySame topicColorectal Cancer Screening and DetectionFrench-language works237,207