MétaCan
Menu
Back to cohort
Record W4231660995 · doi:10.1017/cjn.2019.211

P.118 Excalibur, a novel haptic hand-controller for robot-assisted microsurgery

2019· article· en· W4231660995 on OpenAlexaffvenue
Madeleine de Lotbinière-Bassett, S Choi, S Lama, GR Sutherland, H Hoshyarman

Bibliographic record

VenueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · 2019
Typearticle
Languageen
FieldEngineering
TopicSoft Robotics and Applications
Canadian institutionsCalgary Laboratory Services
Fundersnot available
KeywordsHaptic technologyImaging phantomTask (project management)SimulationComputer scienceEngineeringMedicineNuclear medicine

Abstract

fetched live from OpenAlex

Background: For robot-assisted telesurgery, the workstation, in particular the haptic handcontroller itself a robot, is paramount to the performance of surgery. Based on the requirements for microsurgery, a novel haptic handcontroller Excalibur has been developed. Methods: Thirty-two surgeons performed a peg-in-hole task (simulating micromanipulation) with Excalibur and two commercially available handcontrollers (Sigma 7 and PHANToM Premium 3.0). A modified Kuka endeffector with bipolar forceps, and Leica microscope completed the remote robotic site. Comparisons were made based on training time, task completion time and number of errors. All participants completed a questionnaire. Results: Repeated measures ANOVA demonstrated significance for task completion time (p=0.004), training time (p=0.021) and number of errors (p=0.004). Surgeons were faster with Excalibur (72s) than with Sigma (96s,p=0.005) and PHANToM (96s,p=0.036). Training time was shorter with Excalibur than with PHANToM (210s vs 310s,p=0.013), and users made fewer errors (0.7 vs 2.1,p=0.008). Training time required for Sigma (285s) and the number of errors (1.3) were not significant. The surgeons found Excalibur smoother, more comfortable, less tiring and easier to maneuver, with more realistic force feedback and superior movement fidelity. Conclusions: Surgical performance was superior with Excalibur compared to the other handcontrollers. This may reflect the microsurgical requirements and unique design architecture of Excalibur.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.062
Threshold uncertainty score0.207

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0620.015

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.245
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences NeurologiquesSame topicSoft Robotics and ApplicationsFrench-language works237,207